1700℃ Split Tube Furnace
1. We offer various equipment temperature solutions to meet diverse application requirements. This compact split tube furnace can reach temperatures up to 1700°C. For compact split tube furnaces with other temperatures or requirements, please browse other products on our website or contact sales. We will recommend suitable products and supporting equipment.
2. This compact split tube furnace, like all of our high-temperature furnaces, features a temperature control accuracy of ±1°C, essential for experiments or operations requiring high precision.
- Shenyang Kejing
- Shenyang, China
- 10 working days
- 50 sets
- Information
Introduction of Open Type Vacuum Tube Furnaces:
The OTF-1700X is a single-zone open type vacuum tube furnace. It can heat samples in either vacuum or atmospheric conditions. It features a 60mm outer diameter corundum tube and a 30-step programmable controller, achieving a temperature control accuracy of ±1°C.
Key Features of Open Type Vacuum Tube Furnaces:
·The split tube furnace body is designed to be open for easy tube replacement.
·The split tube furnace utilizes high-purity alumina fiber insulation, making it more energy-efficient.
·The split tube furnace utilizes a double-shell structure and features an air cooling system.
Technical specifications of the split tube furnace:
Product Name | 1700°C Open Tube Furnace OTF-1700X |
Model of split tube furnace | OTF-1700X |
Basic Specifications of split tube furnace | · Power Input of split tube furnace: AC 220V 50/60Hz, Maximum Power: 7kW · Maximum Temperature of split tube furnace: 1650°C ≤ 10 minutes (1600°C ≤ 1 hour) · Long-Term Operating Temperature: 1500°C · Temperature Control Thermocouple: Type B Double Platinum-Rhodium Thermocouple · Heating Zone Dimensions: 400mm (Total Heating Zone Length) · Heating Rate: ≤ 10°C/min below 1400°C; ≤ 5°C/min from 1400°C to 1600°C · Corundum Tube: OD 60mm x ID 54mm x 1000mm (Optional 80mm corundum tube available. Note: Corundum tubes are susceptible to breakage due to inherent material properties and are consumables not covered by warranty). |
Temperature Control System of open type vacuum tube furnace | · Open type vacuum tube furnace is includes an 858P temperature controller (optional Eurotherm instrument for a constant temperature accuracy of ±0.1°C). · Open type vacuum tube furnace is equipped with a PID automatic temperature control system. · Intelligent 30-step programmable control. · Temperature control accuracy of compact split tube furnace: ±1°C. · Default DB9 PC communication port. · All components are UL or MET approved and have passed other relevant safety tests worldwide. · Optional computer temperature control software (for the YD518P series controller) is available for controlling temperature curves and exporting data. |
Stainless Steel Sealing Flange System of open type vacuum tube furnace | ·A compression silicone O-ring seal is used between the sealing flange and the corundum tube flange. ·The left flange is equipped with a precision needle valve, a pointer-type vacuum pressure gauge, and a 6.35 double-ferrule inlet. ·The right flange has a KF25 exhaust port and a pagoda nozzle outlet. |
Vacuum System of compact split tube furnace (Optional) | ·A mechanical pump is available, achieving a vacuum level of 10-2 ttorr. ·A molecular pump is available, achieving a vacuum level of 10-5 ttorr. |
Dimensions of compact split tube furnace | 1000mm(L)*610mm(W)*750mm(H) |
Weight of compact split tube furnace | Approximately 150kg |
Shelf Life | 1 year (excluding consumable parts such as the furnace tube, fluoropolymer O-rings, and heating elements) |
Precautions of compact split tube furnace | · The pressure inside the corundum tube must not exceed 0.02 MPa; · Due to the high pressure inside the gas cylinder, a pressure reducing valve must be installed on the cylinder when introducing gas into the quartz tube. To ensure safety, we recommend operating at a pressure below 0.02 MPa. We recommend purchasing a pressure reducing valve from our company, which has a range of 0.01 MPa-0.1 MPa, for greater accuracy and safety. · For sample heating experiments, it is not recommended to close the exhaust and inlet valves at the flange end of the furnace tube. If you need to close the valves to heat the sample, always monitor the pressure gauge. If the pressure reading exceeds 0.02 MPa, immediately open the vent valve to prevent accidents (such as furnace tube rupture, flange flying off, etc.). · We do not recommend the use of flammable, explosive, or toxic gases. If your process requires the use of flammable, explosive, or toxic gases, please implement appropriate protective and explosion-proof measures. The company assumes no responsibility for any problems caused by the use of flammable, explosive, or toxic gases. · The equipment must operate on an independent power grid within a ±8% voltage range. It must not share a power grid with high-magnetic-field generating equipment, such as medium-frequency or high-frequency equipment, and must not be located in the same room as such equipment. If this is not possible, perform harmonic detection and control on the power grid and perform electromagnetic isolation on the equipment. · Keep the equipment away from areas subject to liquid splashing. · Keep the equipment away from areas subject to magnetic or conductive powders. · The insulation and heating elements are consumable components. Cracks in the insulation material during sintering are normal and can be repaired with a repair agent. The heating elements are consumable components. If the furnace fails to reach operating temperature or heats up noticeably slowly after extended use, contact the manufacturer to determine whether they need replacement. · This equipment has a high-precision temperature control range of 300-1600°C. Temperature fluctuations may occur at low temperatures. · Operating the furnace above 500°C is not recommended. |
Compliance | CE Certified, UL or CSA certification is available at extra cost. |
About us:
Our company specializes in the research, development, and sales of laboratory equipment, providing high-quality, high-tech lab equipment to numerous international clients.
We can tailor laboratory equipment to meet your individual needs. Please contact our customer service team for more information.
We also offer 24/7 customer service. If you encounter any issues or other difficulties, please contact us for answers.
If you have purchased or are planning to purchase any of our equipment, you will undoubtedly appreciate our professionalism, precision, and efficiency.